Smile Center Air Flow Machine Training
Start Here
How the Machine Works
1 / 11

How the Air Flow Machine Works

AIR
+
CLEANING POWDER
+
DISTILLED WATER
CLEANING SPRAY
DISTILLED WATER ONLY — EVERY TIME
Core principle: Air mixes with cleaning particles and water to remove plaque, bacteria, stain, and buildup from tooth surfaces.

Know the Machine Parts

CART

Wheeled cart

The unit sits on a mobile cart and connects to the operatory's air output.

DISTILLED WATER

Water chamber/bottle

Fill with distilled water only. Check the level before starting.

POWDER

Cleaning powder chamber

Contains the cleaning powder used by the Air Flow handpiece.

2 POWDERS

Supra- and subgingival powders

Use the correct powder for the procedure. The fast powder is used for most regular cleanings.

HANDPIECE 1

Prophy / scaling handpiece

Used with the machine's compatible Cavitron-style tip.

HANDPIECE 2

Air Flow cleaning handpiece

Delivers the air + powder + water cleaning spray.

WIRELESS PEDAL

Air Flow foot pedal

The Air Flow unit uses its own wireless pedal. Keep it charged and ready for use. The Cavitron/scaler has a separate pedal.

Setup Before Every Patient

CONNECT TO AIR
CHECK DISTILLED WATER
CHECK POWDER
SELECT HANDPIECE
Connect to AIR OUTPUT only. If the machine is accidentally connected to the water output instead of air, it can stop working.
NEVER CONNECT THE MACHINE TO THE WATER OUTPUT
Pedal rule: Keep the Air Flow wireless pedal charged. The Cavitron/scaler uses a separate pedal, so do not mix them up. If the Air Flow pedal battery is discharged, connect the pedal with its cable and use it while connected.
  • Confirm there is enough distilled water for the procedure.
  • Confirm there is enough cleaning powder.
  • Confirm the correct powder is loaded.
  • Confirm the correct handpiece/tip is installed.
  • Confirm the Air Flow wireless pedal is charged.
  • Make sure you are using the Air Flow pedal, not the separate Cavitron pedal.
  • If the wireless pedal is discharged, connect it with the cable so it can be used while connected.
  • Set up high-volume suction before beginning.

The Four Main Controls

POWERControls the amount/intensity of air and particles.
WATERControls water volume.
TEMPControls water temperature.
PURGEFlushes/clears the system after use.
Recommended starting point: Temperature 3, medium water, medium air/power. Adjust as needed.
For heavier stain or less-sensitive patients, settings may be increased as needed. Always keep enough water flowing for safe, comfortable use.

Correct Clinical Technique

ANGLE

Hold the handpiece at an angle

Direct the spray toward the coronal/tooth surface, not straight into the gingiva.

SOFT TISSUE

Never point directly at soft tissue

Direct spraying at gingiva or other soft tissue may injure or irritate the tissue.

WATER

Maintain adequate water

Do not run the cleaning spray too dry. Adjust water and power together as needed.

SUCTION

Use suction

This is easier with an assistant who can hold suction and control excess water/powder.

Do not shoot water or Air Flow spray directly at the gums. Keep the handpiece away from the tissue and angled toward the tooth.

Use Only Air Flow-Compatible Cavitron Tips

ONLY USE THE CAVITRON TIPS MADE FOR THIS AIR FLOW UNIT

The tip connection/thread is different from a regular Cavitron.

CorrectWrong
Use the Air Flow-specific compatible Cavitron tip.Do not use a regular Cavitron tip just because it looks similar.
Thread/install it gently by hand.Never force a tip that does not fit easily.
If there is resistance, stop and verify the tip.Forcing the wrong thread can damage the handpiece/unit.
Important: A wrong tip can damage the Air Flow handpiece, and attempting to use the wrong threaded tip can also damage regular Cavitron components.
KEEP AIR FLOW CAVITRON TIPS SEPARATE FROM REGULAR CAVITRON TIPS
Storage rule: Air Flow-compatible Cavitron tips must be stored in a separate, clearly identified location from regular Cavitron tips. This helps prevent staff from accidentally mixing them or attempting to install the wrong threaded tip.

The Most Important Step: PURGE

PURGE THE SYSTEM AFTER EVERY USE

Powder left inside the tubing can mix with moisture and clog the system.

FINISH CLEANING
ACTIVATE PURGE
CLEAR PARTICLES FROM TUBING
PROTECT THE MACHINE
If you skip purging: water/moisture can cause particles to clump inside the tubes. The lines can clog and the machine may stop working.
My rule: I do not leave the operatory until the system has been purged.

Sterilize the Handpiece Between Patients

STERILIZE THE HANDPIECE BETWEEN EVERY PATIENT / USE
AFTER USE

Remove contaminated components safely

Handle the handpiece/tip as a contaminated clinical item after treatment.

STERILIZATION

Follow Smile Center sterilization protocol

Process the handpiece and reusable tip/components according to the approved office/manufacturer sterilization instructions.

Do not simply wipe and reuse a reusable handpiece between patients. Complete the required sterilization process.

Common Problems and What to Check

ProblemFirst things to check
No/poor air flowConfirm the cart is connected to the air output, not water.
Weak cleaning sprayCheck powder level, power setting, water setting, and handpiece connection.
Machine starts cloggingThink about whether purge was completed after the previous use. Moisture + powder can clog tubing.
No water / low waterCheck the distilled-water level and water setting.
Water is coming out but no powderThe powder system may be clogged. Purge the system multiple times. If powder flow does not return, stop using the unit and contact the manager for additional troubleshooting.
Air Flow pedal is not respondingCheck whether the wireless pedal is charged. Confirm you have the Air Flow pedal and not the separate Cavitron pedal. If the battery is discharged, connect the pedal with the cable and use it while connected.
Cavitron tip will not thread smoothlyStop. Verify it is an Air Flow-compatible tip. Never force it.
Water but no powder: Treat this as a possible clog. Purge several times. If the problem continues, contact the manager for additional troubleshooting rather than repeatedly operating the machine.
If something does not fit or the machine behaves abnormally, stop. Do not force components or keep running the machine when the cause is unclear.

How to Explain & Offer Air Flow

$60 EXTRA — ALWAYS

Every patient should receive a simple explanation of what Air Flow is and why they may want to upgrade their cleaning.

KEEP IT SIMPLE

Explain the benefit in patient-friendly language.

Air Flow uses a controlled stream of air, distilled water, and fine cleaning powder to help remove plaque, bacteria, buildup, and surface stains from the teeth.

PRICE

The upgrade is $60.

I clearly tell the patient that Air Flow is an additional $60. I do not change the price or present it as included in the regular cleaning.

FIRST-TIME TRIAL

First-time patients may try it with a money-back guarantee.

The money-back guarantee is used only when a patient is trying Air Flow for the first time and is unsure whether they will like the new technology.

RETURNING AIR FLOW PATIENT

No repeated money-back guarantee.

If the patient has already tried Air Flow before, I can explain the service and the $60 upgrade, but I do not offer the first-time money-back guarantee again.

Suggested patient explanation:

“We also offer Air Flow, which is an upgraded cleaning technology that uses air, water, and a fine cleaning powder to remove plaque, bacteria, buildup, and stains. It is an additional $60.”
For a patient trying Air Flow for the first time:

“If you would like to try it today, we offer a money-back guarantee the first time you try the technology. If you do not feel that you liked the Air Flow upgrade, let us know.”
Important: The money-back guarantee is a first-time trial offer only. Do not promise it every time the patient receives Air Flow.

If the patient wants Air Flow at their next cleaning

PATIENT WANTS AIR FLOW NEXT TIME
ADD AIR FLOW TO APPOINTMENT NOTE
ADD 5 EXTRA MINUTES
AIR FLOW NEXT VISIT = ADD 5 MINUTES TO THE APPOINTMENT
SCHEDULING

Give the clinical team enough time.

When a patient requests Air Flow for the next visit, add 5 extra minutes to the cleaning appointment.

APPOINTMENT NOTE

Make the request visible.

Add a clear note that the patient wants Air Flow so the hygienist/clinical team can prepare the machine and supplies before the appointment.

My Air Flow offer: Explain it clearly → tell the patient it is $60 extra → first-time patient may receive the trial guarantee → if they want it next time, document it and add 5 minutes.

Air Flow Checklist

BEFORE

  • Connect to AIR output.
  • Use distilled water only.
  • Check water level.
  • Check powder level/type.
  • Use correct Air Flow-compatible tip.
  • Keep the Air Flow wireless pedal charged.
  • Confirm you have the Air Flow pedal — the Cavitron has a separate pedal.
  • If the pedal battery is dead, connect it with the cable.
  • Set temperature 3, medium water/air as starting point.
  • Set up suction.
  • Confirm whether the patient selected the $60 Air Flow upgrade.

DURING

  • Hold handpiece at an angle.
  • Aim toward coronal tooth surface.
  • Do not point at soft tissue.
  • Maintain adequate water.
  • Adjust power/water for stain and sensitivity.
  • Use assistant/suction when possible.

AFTER

  • PURGE THE SYSTEM.
  • Confirm powder/particles are cleared.
  • Remove reusable handpiece/tip safely.
  • Sterilize handpiece between patients.
  • Prepare the unit for the next patient.

NEVER

  • Never use tap water.
  • Never connect to water output.
  • Never force the wrong Cavitron tip.
  • Never store Air Flow Cavitron tips mixed with regular Cavitron tips.
  • Never point directly at gums/soft tissue.
  • Never skip purge.
  • Never reuse an unsterilized handpiece.

Air Flow Machine Quiz

Choose the best answer. Passing target: 90%.

1. What type of water should always be used?

Use distilled water only.

2. The cart should be connected to which operatory output?

The machine connects to the air output.

3. What is the most important step after cleaning?

Always purge after use to prevent clogs.

4. Why can the tubing clog?

Moisture can clump the powder and block tubing.

5. How should the Air Flow handpiece be aimed?

Keep the spray off soft tissue and angle it toward the tooth.

6. What are the recommended starting settings?

Start at temp 3 and medium water/air, then adjust.

7. A Cavitron tip does not thread easily into the Air Flow handpiece. What should you do?

Never force the wrong thread.

8. Which Cavitron tips should be used?

Only use tips designed for this Air Flow unit.

9. What should happen to the reusable handpiece between patients?

Sterilize reusable handpieces between patients.

10. Why is an assistant helpful during Air Flow cleaning?

Suction makes the procedure easier and cleaner.

11. How much does the Air Flow upgrade cost?

Air Flow is always an additional $60.

12. Who should be offered the Air Flow money-back guarantee?

The guarantee is only for a first-time patient trying the technology.

13. A patient says they want Air Flow at their next cleaning. What should you do?

Document the request and add 5 extra minutes to the appointment.

14. Which is the best way to explain Air Flow to a patient?

Keep the explanation simple, accurate, and clear about the $60 additional charge.

15. Water is coming through the Air Flow handpiece, but no powder is coming out. What should you do first?

Water with no powder may indicate a clog. Purge multiple times; if unresolved, contact the manager.

16. How should Air Flow Cavitron tips be stored?

Keep Air Flow tips separate because the threads differ and using the wrong tip can damage equipment.

17. What should you do with the Air Flow wireless pedal between uses?

Keep the Air Flow wireless pedal charged. The Cavitron has its own separate pedal.

18. The Air Flow pedal battery is discharged. What can you do?

If the wireless pedal is discharged, connect it with its cable. Do not substitute the Cavitron pedal.